PVP260kW
The industry
standard for reliability, installability and
maintainability
The PV Powered 260kW has raised the bar once
again for commercial inverter reliability, ease
of installation and lifetime maintainability.
High reliability is enabled by market-leading
features including busbar power connections,
redundant cooling system, card cage circuit
board design and the widest temperature rating
of any inverter in its class. The highly
integrated system saves installers time and
money by including loadrated AC & DC service
disconnects, neutral-free installation,
oversized busbar landings and generous cable
bending area for top, bottom and side cable
entry options.
The PVP260kW has a standard 295VDC minimum MPPT
and an optional full power 265VDC minimum MPPT-
the lowest MPPT voltage of any commercial
inverter in the industry. This low input voltage
option enables exceptional stringing capability
with all PV module technologies including new
thin film modules. The PVP260kW also simplifies
performance monitoring by offering
inverter-integrated solutions from market
leaders Fat Spaniel, Draker and Energy
Recommerce. Additional options from PV Powered
include integrated revenue grade meter and
subcombiner monitoring.
PV Powered backs all its commercial inverters
with an industry-leading 10-year nationwide
warranty and an unprecedented optional 20-year
warranty; plus the best service and support team
in the business.
Features
Superior Reliability
• Redundant cooling system with Smart Air
Management™
• Low parts count reduces potential failure
points
• Engineered busbar power connections
• Card cage circuit board system minimizes
electronic interconnections
Exceptional Installability
• Top, bottom and side entry with generous
bending area and oversized busbar landings
• Large DC sub-combiner compartment with
multiple fuse options
• Full power output at 265 VDC enables more
PV array design options
• Exterior mounting flanges for fast and
easy anchoring with no pre-drilling
Easy to Maintain
• All maintenance and service via front
access
• Fast change circuit board system shortens
service time
• Load-rated AC and DC service disconnects
|
Electrical Specifications
|
|
|
Model |
260kW |
260kW-LV |
|
|
|
|
|
Continuous Power
Output (kW) |
260kW
|
260kW |
| |
|
Weighted CEC
Efficiency (%) |
96.5 (est) |
96.5 (est) |
| |
|
Maximum DC
Input Voltage
(VOC) |
600 |
600 |
| |
|
DC Peak Power
Tracking Range
(V) |
295-500 |
265-500 |
| |
|
DC Isc Maximum
Current (A) |
918 |
1022 |
| |
|
AC
Nominal Voltage
(V) |
480 |
480 |
| |
|
AC
Operating Range
(V) |
422-528 |
422-528 |
| |
|
AC
Frequency Range
(Hz) |
59.3-60.5 |
59.3-60.5 |
| |
|
AC Maximum
Continuous
Current (A) |
301 |
301 |
| |
|
Standby Losses
(W) |
<75 (est)
|
<75 (est) |
|
|
|
|
|
Harmonic
Distortion (%THD) |
<3% |
<3% |
|
|
|
|
|
Power
Factor |
>.99 |
>.99 |
| |
|
|
|
Mechanical Specifications
|
Model |
260kW |
260kW-LV |
|
|
|
|
|
Enclosure |
NEMA 4 |
NEMA 4 |
| |
|
Construction |
Powder Coated
Steel |
Powder Coated
Steel |
| |
|
Mounting |
Pad Mount |
Pad Mount |
| |
|
Weight (lbs) |
4,800 |
4,800 |
| |
|
Cooling |
Forced
Convection |
Forced
Convection |
| |
|
Temperate Range
(ºC) |
-30 to 50 |
-30 to 50 |
| |
|
Isolation
Transformer |
Yes |
Yes |
| |
|
Mechanical Specifications
UL 1741,
IEEE519,
IEEE929,
IEEE1547
FCC Class A for
conducted and
radiated |
|
|
|
 |