Electrical Specifications |
|
|
PV Amps (Max.) |
|
12 A at 12 VDC only |
|
|
DC Load (Max.) |
|
12 A with auto reset |
|
|
Operating Voltage (Min.) |
|
6 V |
|
|
Voltage Drop - PV to
Battery
(Max.) |
|
0.3 V |
|
|
Voltage Drop -
Battery
to DC Load (Max.) |
|
0.15 V |
|
|
Regulation Setting |
|
13 to 15 VDC |
|
|
Equalize Setting |
|
Bulk plus 1 V for two hours |
|
|
Consumption while charging (typical) |
|
0.007 A |
|
|
Consumption at night (typical) |
|
0.003 A |
|
|
Consumption with load disconnected (typical) |
|
0.003 A |
|
|
Stranded wire size (Max.) |
|
#10 AWG stranded (5.4 mm2) |
|
|
General Specifications |
|
|
Allowed
Temperature
Range |
|
32° F to 104° F (0° C to 40° C) |
|
|
Enclosure Type |
|
Powder coated steel with strain relief for
wiring and knockouts for up to three 1/2"
conduits |
|
|
Unit Weight |
|
2 lb (0.9 kg) |
|
|
Shipping Weight |
|
2.5 lb (1.13 kg) |
|
|
Dimensions (H x W x D) |
|
6.25 x 4.3 x 1.5" (16.5 x 11 x 4 cm) |
|
|
Shipping Dimensions (H x W X D) |
|
8 x 4.6 x 1.6" (20.3 x 11.7 x 4 cm) |
|
|
Mounting |
|
Vertical wall mount - indoor |
|
|
Warranty |
|
Two years |
|
|
Part Numbers |
|
C12 - charge controller |
|
|
|
|
BTS - optional battery temperature sensor |
|
|
Features & Options |
|
|
Regulation Method |
|
Standard - three stage (bulk, absorption and
float), solid state, pulse width modulation |
|
|
Field Adjustable Control Setpoints |
|
Standard - removable knobs and calibrated scales |
|
|
Setting Protection |
|
Standard - knobs can be removed to prevent
tampering |
|
|
Testpoints |
|
Standard - provided for each setting |
|
|
Automatic Equalization |
|
Standard - every 30 days or after voltage
reaches low voltage disconnect - can be disabled |
|
|
External
Battery
Temperature Compensation |
|
Optional - battery temperature sensor (BTS) |
|
|
Short Circuit Protection |
|
Standard - fully electronically protected with
auto reset and manual reset switch, protects
both the loads and PV array from damage from
short circuits - a fuse for the battery is still
advised to protect the battery wires if located
separately |
|
|
Reverse Polarity Protection |
|
Standard - fully protected |
|
|
Low Voltage Disconnect |
|
Standard - adjustable automatic or manual
operation, manual reconnection includes warning
flash of loads five minutes before and ten
minutes grace period |
|
|
|
|
|
|
|
|
|
Note:
Specifications subject to change without notice. |